| Sign In | Join Free | My benadorassociates.com |
|
Brand Name : IFM
Model Number : KQ1001
Certification : CE
Place of Origin : china
MOQ : 1
Price : USD$220
Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
Delivery Time : 6-8weeks
Packaging Details : carton
Communication interface : IO-Link
Dimensions [mm : 1
Current consumption [mA : 1
Protection class : III
| Electrical design | PNP/NPN; (configurable) |
|---|---|
| Communication interface | IO-Link |
| Dimensions [mm] | 250 x 28 x 16.7 |
| Application | Continuous level measurement behind non-metallic and non-conductive surfaces |
|---|---|
| Media | dry bulk material; aqueous solutions; oils |
| Cannot be used for | very adhesive media |
| Operating voltage [V] | 10...30 DC; (IO-Link: 18...30 DC) |
|---|---|
| Current consumption [mA] | < 50 |
| Protection class | III |
| Reverse polarity protection | yes |
| Max. power-on delay time [ms] | 1300 |
| Measuring principle | capacitive |
| Number of inputs and outputs | Number of digital outputs: 3 |
|---|
| Electrical design | PNP/NPN; (configurable) |
|---|---|
| Number of digital outputs | 3 |
| Permanent current rating of switching output DC [mA] | 200 |
| Max. resistance switching output [Ω] | 8 |
| Short-circuit protection | yes |
| Type of short-circuit protection | yes (non-latching) |
| Overload protection | yes |
| Measuring range [mm] | < 200 |
|---|
| Detection range [mm] | 228 |
|---|---|
| Set point SP [%] | 5...95 |
| Reset point rP [%] | 4...94 |
| In steps of [%] | 1 |
| Repeatability [% of the final value] | 2 |
|---|---|
| Offset deviation [% of the final value] | 4 |
| Resolution [% of the final value] | 1 |
| Linearity deviation [% of the final value] | 1 |
| Response time [ms] | 1300 |
|---|
| Parameter setting options | Damping; hysteresis / window; fault indication; Diagnostic function; Sensitivity; internal temperature; limitation of measuring range; adjustable switching delay; zero-point calibration; direction of installation; LEDs can be deactivated |
|---|
| Communication interface | IO-Link | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Transmission type | COM2 (38,4 kBaud) | ||||||||||
| IO-Link revision | 1.1 | ||||||||||
| SDCI standard | IEC 61131-9 | ||||||||||
| Profiles | Digital Measuring Sensor Profile, Common Profile | ||||||||||
| SIO mode | yes | ||||||||||
| Required master port class | A | ||||||||||
| Process data analog | 1 | ||||||||||
| Process data binary | 3 | ||||||||||
| Min. process cycle time [ms] | 9.6 | ||||||||||
| IO-Link process data (cyclical) |
|
||||||||||
| IO-Link functions (acyclical) | direction of installation; limitation of sensor elements; Sensitivity; minimum recognition threshold; Performance in case of a fault; error delay; Damping; LED mode; switch-on cycle counter; operating hours counter; switching cycles counter; min./max. process value; internal temperature; min./max. internal temperature; diagnostic data level | ||||||||||
| Supported DeviceIDs |
|
||||||||||
| Note |
|
| Applications | DIN EN 60654-1 application class B2 |
|---|---|
| Ambient temperature [°C] | -20...80 |
| Storage temperature [°C] | -25...85 |
| Protection | IP 65 |
| EMC |
|
||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Shock resistance |
|
||||||||||||||
| Vibration resistance |
|
||||||||||||||
| MTTF [years] | 290.43 | ||||||||||||||
| UL approval |
|
| Weight [g] | 377.5 |
|---|---|
| Dimensions [mm] | 250 x 28 x 16.7 |
| Material | PBT; PC; |
| Display |
|
|---|
| Items supplied |
|
||||
|---|---|---|---|---|---|
| Accessories (optional) |
|
| Remarks |
|
|
|---|---|---|
| Pack quantity | 1 pcs. |
| Connection | Connector: 1 x M12; coding: A |
|---|
| Cable: 0.1 m, PUR |
|
|
IFM Continuous Level Sensor KQ1001 KQ-5xxxNFPKG/IO/0,1M/US IO-Link Images |